Common Taurus 605 Poly Problems and Their Solutions

The Taurus 605 Poly is a popular revolver that is known for its lightweight and compact design, making it a great choice for concealed carry. However, like any firearm, the Taurus 605 Poly is not immune to problems.

If you are a Taurus 605 Poly owner, you may have experienced issues such as cylinder binding, misaligned cylinder, failure to eject, light primer strikes, and loose front sight.

Taurus 605 Poly problems

Don’t worry though! In this blog post, we will discuss these common problems and provide you with practical solutions to help you keep your Taurus 605 Poly in top working condition.

So, whether you are a new owner or have been using your revolver for years, read on to learn how to address these common issues and ensure your firearm is always ready when needed.

The common problems with Taurus 605 Poly gun are Failure to Feed, Trigger Getting Stuck, Cylinder Won’t Close, Fiber Optic Broken or Missing, Hammer Problems, Poor Accuracy, Failure to Return to Battery and The cylinder Won’t Release.

Common Taurus 605 Poly Problems and Their Solutions

Problems Solution
Failure to Feed Clear debris or fouling in the chamber, magazine, or feed ramp; clean and lubricate the firearm.
Trigger Getting Stuck Inspect for debris or wear in the trigger mechanism; clean, lubricate, or replace as necessary.
The cylinder Won’t Close Remove debris or fouling in the cylinder or ejector rod; clean and lubricate the firearm.
Fiber Optic Broken or Missing Replace the fibre optic sight with a new one.
Hammer Problems Inspect for debris or wear in the hammer mechanism; clean, lubricate, or replace as necessary.
Poor Accuracy Check the sights for proper alignment; practice proper shooting technique; consider using higher-quality ammunition.
Failure to Return to Battery Inspect for debris or wear in the slide and recoil spring assembly; clean, lubricate, or replace as necessary.
The cylinder Won’t Release Inspect for debris or wear in the cylinder release mechanism; clean, lubricate, or replace as necessary.

1. Failure to Feed

Are you having trouble with your Taurus 605 Poly feeding correctly? If so, do not worry as there are a few steps to take in order to diagnose and fix the issue.

While there are many potential explanations for why a gun may fail to feed, we will cover the most common causes and provide step-by-step instructions for fixing them.

To begin, check if the magazine is properly inserted into the gun and that it is seated all of the ways.

The magazine should click into place when fully inserted. If not, try slightly angling or tilting the magazine when reinserting it.

Additionally, inspect the magazine spring and follower for dirt or grime which may be preventing proper insertion or removal from the gun. Clean these components if necessary.

Next, examine any ammunition being used to ensure that it is clean and undamaged. Incorrectly sized rounds, too much lubrication on bullets, or bent cases can prevent reliable cycling of rounds through the firearm’s action.

Discard any rounds that appear damaged or have unusual characteristics and replace them with factory-made ammunition of the correct size and calibre for your specific firearm model.

Finally, inspect the barrel chamber for obstructions such as dirt, debris or build-up from previous shooting sessions which can impair feeding reliability as well as accuracy in general.

Remove any foreign objects found inside with a cleaning brush designed specifically for this purpose and lubricate moving parts such as rails and springs according to the manufacturer’s instruction manuals to maximize performance overall.

With these steps completed your Taurus 605 Poly should now feed reliably once again!

2. Trigger Getting Stuck

This can be a frustrating situation, but there are some steps you can take to fix it.

Here we’ll walk through the most common causes and how to remedy them.

The first cause could be the sear spring, which is located beside the safety.

The sear spring ensures that the trigger moves freely and when it becomes worn out or bent, it will reduce the movement of the trigger and cause it to stick.

To fix this issue, check if your sear spring is bent or loose. If so, replace it with a new one and re-adjust it as needed.

Another common culprit is dirt or debris buildup inside of the trigger assembly. This can create friction which hinders its movement and makes it stick in place.

To resolve this issue, disassemble the gun and clean off any dirt or debris from within the trigger assembly using cleaning solvent and a soft cloth.

Once cleaned, lubricate all moving parts with oil before reassembling everything correctly.

The third potential cause is improper installation of parts such as trigger screws or pins not secured properly in place.

Make sure that all pins are properly aligned with their slots before tightening up the screws.

Additionally, use blue Loctite on screws for better security if needed.

Finally, if none of these solutions works, then consider taking your gun to a certified gunsmith for repair as there may be internal damage or other unseen issues causing the problem.

3. Cylinder Won’t Close 

Are you having trouble with your Taurus 605 Poly revolver not closing properly?

Have you noticed that the cylinder isn’t able to fully rotate and the hammer won’t drop into the firing position? If so, then you may be dealing with an issue of the cylinder not being able to close.

This problem can be caused by a few different factors, such as improper alignment of components within the gun, rust or dirt in the mechanisms, or misalignment of parts from use or abuse.

To get your revolver back in working condition it’s important to troubleshoot all possible causes.

Here are some steps you can take:

First, inspect the gun for any signs of damage or wear and tear. Look for anything out of place, like loose screws or pins, bent parts, corrosion on the internal components, etc.

Additionally, if there is the lubricant in the gun, make sure that it is still fresh and at proper levels.

Next, check to see if any parts are misaligned due to use or abuse. Make sure that all parts are properly aligned and functioning correctly before attempting any repairs.

In particular, double-check that both the internal and external components of the cylinder are properly lined up with each other and nothing is blocking them from moving freely.

Finally, remove any dirt or debris that may have built up in between components over time.

Make sure to use a soft cloth dampened with cleaning solvent to avoid damaging any internal parts while cleaning them out.

Once all pieces have been cleaned and inspected for wear/tear/damage they can be reassembled and tested for proper function again until a resolution is reached.

By following these steps you should be able to diagnose why your Taurus 605 Poly revolver won’t close correctly and repair it accordingly.

Taurus 605 Poly Problems

4. Fiber Optic Broken or Missing

This is a common problem amongst many users that can be caused by a number of factors.

In order to figure out the cause of this issue and determine the best solution, it is important to understand what all could be causing it.

One common cause for this issue is if the cylinder has been manually locked open, meaning that there is something blocking the cylinder from closing properly after it has been turned off.

In order to ensure that this isn’t the cause and move forward with other potential solutions, make sure that all manual locks are removed or disengaged.

Another possible explanation for when your Taurus 605 Poly cylinder won’t close could be related to temperature regulation issues.

If the temperature around the cylinder gets too cold, then the air inside of it could expand and prevent it from closing correctly.

If this is likely to be causing your problems, try making sure that your environment is better regulated in terms of temperature and see if that resolves the issue.

It’s also possible that there could be a technical fault with either the valve or its internal mechanisms causing your Taurus 605 Poly cylinder not to close correctly.

If you think this may be the case, then you should contact an experienced professional and have them look at the cylinder internals and diagnose the problem accurately.

After they have identified any possible faults they will be able to provide you with a more detailed plan on how best to fix them.

Finally, malfunctioning electrical components could also contribute to why your Taurus 605 Poly cylinder won’t close properly as well.

All cylinders have various sensors and wiring components inside them which can become faulty over time due to wear and tear or simply because of age – particularly if they haven’t had regular maintenance done on them over their lifetime. Before trying anything else, make sure these components are functioning properly and replace anything which may have developed a fault recently.

5. Hammer Problems

Are you experiencing problems with your Taurus 605 Poly hammer? If so, this guide can help you identify and address the most common causes.

To begin, let’s look at some of the possible underlying issues that can lead to hammer problems in this model.

The first common cause of issues with the Taurus 605 Poly is a lack of power. The motor may be failing to provide sufficient torque for the tool to work effectively, or the battery may be too weak to maintain its charge.

This could be due to a faulty connection or an issue with the charging system. In any case, it is important to check that all parts are functioning correctly before attempting to rectify any other suspected causes.

Another potential trigger for hammer problems in the Taurus 605 Poly is a problem with its internal mechanisms.

For example, if there is an obstruction in its airways, this could stop air from reaching the pistons and prevent them from working correctly when activated.

Additionally, if there is a fault with one or more components within its structure – such as its bearings or gears – then this could also affect how it functions over time.

A third cause of issues with this model may also be related to dirt and debris buildup within its parts or housing units.

As dust and other particles accumulate over time, they can muffle sound output and restrict airflow throughout the device’s components.

Try cleaning out any blocked vents or crevices regularly using compressed air cans in order to ensure optimal performance from your hammer drill.

Finally, another less-common cause of problems with the Taurus 605 Poly may be related to improper use and maintenance habits on behalf of its users.

If safety procedures such as wearing protective gear while operating tools are not followed correctly – or if tools are used beyond their recommended capacity – then these activities can wear down components more quickly than expected and lead to frequent breakdowns and malfunctions over time.

6. Poor Accuracy

Have you ever experienced poor accuracy when using the Taurus 605 Poly? This is a common issue that can arise with any measuring instrument, but it’s important to understand the potential causes so that you can find a solution.

Some of the most common causes of poor accuracy in the Taurus 605 Poly include incorrect calibration settings, lack of maintenance, and operator error.

One of the most common causes of inaccurate measurements made with the Taurus 605 Poly is incorrect calibration settings.

The Taurus 605 Poly should be calibrated regularly to ensure accurate results. If it has not been recently calibrated, or if it was calibrated improperly, then this could lead to inaccurate measurements.

To address this issue, it is important to have your Taurus 605 Poly professionally calibrated according to manufacturer instructions.

Lack of regular maintenance can also lead to inaccurate measurements from your Taurus 605 Poly.

It is important to ensure that all parts are functioning properly and clean from dust and dirt buildup. If a part is malfunctioning or dirty, then this could lead to inaccurate readings.

To prevent this from occurring, it is recommended that you schedule regular maintenance for your device. This will help keep all its parts working correctly and produce accurate results every time.

Finally, operator error can also cause poor accuracy in the Taurus 605 Poly. Inaccurate readings may result if an operator does not use the device correctly or fails to follow manufacturer instructions correctly when conducting tests or measurements with the instrument.

To avoid this issue, make sure all operators are properly trained on how to use the device correctly according to manufacturer guidelines before conducting any tests or measurements with it.

7. Failure to Return to Battery

To help narrow down the possibilities and find the solution, we will look at some of the most common causes for failure to return to battery in this handgun, excluding a faulty magazine.

One possible cause of this problem is an improperly installed or damaged recoil spring or guide rod.

If either part has been replaced with an incorrect size or model, it can prevent the slide from functioning correctly and locking back into the battery.

To verify that they are both in good working order, inspect them closely for any signs of wear or damage as well as proper installation.

If either needs to be replaced, make sure to use only OEM parts that are properly sized for your Taurus 605 Poly.

Another common cause for failure to return to the battery is an over-lubricated slide mechanism.

Too much oil or grease can create excessive friction between the slide rails and frame, decreasing the pistol’s performance by preventing it from cycling properly.

Make sure not to over-lube your handgun and apply a light coat of oil instead if necessary. Additionally, cleaning off any existing lubricants on the frame rails can help improve performance as well.

The last potential cause is a worn out extractor claw.

Over time this component can become damaged or bent which will prevent it from hooking onto and holding rounds in place when chambered, leading to malfunctions such as failure to return to battery.

Inspecting and replacing it with an OEM part if needed should fix this issue quickly without requiring any other parts or modifications.

8. Cylinder Won’t Release

While there are several potential causes for this problem, here’s what you need to know about the most common ones and how to fix them.

One of the most common causes of a cylinder that won’t release in a Taurus 605 Poly is due to an incorrectly adjusted latch.

This can happen when the latch isn’t completely flush with the cylinder or is too tight or too loose when it is being closed or opened. To fix this issue, make sure that the latch is properly aligned with the cylinder by adjusting it as needed.

A second cause of a stuck Taurus 605 Poly cylinder may be due to a worn out lock cylinder itself. The internal components of the lock can become worn over time, making it difficult for the key to turn and unlock it.

If this is the case, then replacing the lock cylinder with a new one is usually necessary in order for it to work properly again.

It could also be possible that your Taurus 605 Poly has become jammed from dirt and debris build-up inside its mechanism.

To solve this problem, remove any visible dirt and use an air compressor or canned air duster to blow away any remaining debris within the lock mechanism itself.

Finally, if none of these solutions have worked thus far, then it may be necessary to take apart and reassemble your Taurus 605 Poly in order to release its internal components and clean out any stubborn debris lodged within its mechanism.

This process should only be done by someone trained in locksmithing as improper disassembly may damage your lock permanently.

If all else fails, then you should consult a knowledgeable locksmith as they will have the specialized tools and expertise that are needed to open up and repair your Taurus 605 Poly quickly and effectively.

A professional locksmith will also know exactly what needs to be done in order to get your stuck cylinder unlocked again safely without damaging it further.

Taurus 605 polymer Specs

        Specification Details
Calibre .357 Magnum or .38 Special
Capacity 5 rounds
Barrel Length 2 inches
Overall Length 6.5 inches
Weight 19 ounces
Sights Fixed front and rear
Finish Matte black or stainless steel
Trigger Double action, with a smooth pull
Frame Polymer

Frequently Asked Questions.

What is the weight of Taurus 605 Poly?

Taurus 605 Poly weighs only 19 ounces, making it easy to carry and handle.

What is the capacity of Taurus 605 Poly?

Taurus 605 Poly has a 5-round cylinder capacity.

What is the frame of Taurus 605 Poly made of?

Taurus 605 Poly features a polymer frame, which contributes to its lightweight design.

What is the barrel length of Taurus 605 Poly?

Taurus 605 Poly has a 2-inch barrel length.

Is Taurus 605 Poly suitable for concealed carry?

Yes, Taurus 605 Poly is a popular choice for concealed carry due to its lightweight and compact design.

What is the price range of Taurus 605 Poly?

The price of Taurus 605 Poly varies depending on the retailer and region, but it generally falls between $300 to $400.

Conclusion

the Taurus 605 Poly is a reliable and versatile revolver that is suitable for self-defense and concealed carry. Like any firearm, it can experience issues, but most of these problems are easy to fix with some troubleshooting and regular maintenance.

By understanding the common Taurus 605 Polymer problems and their solutions, you can keep your revolver in top condition and enjoy its many benefits for years to come.

However, it’s worth noting that owning a firearm comes with a great responsibility. It’s crucial to always prioritize safety, proper training, and secure storage.

While addressing common problems can improve the performance of your Taurus 605 Polymer, it’s equally important to have a deep understanding of firearm safety principles and to always follow them without exception.

Let us all remember that responsible gun ownership is a privilege, and with it comes an obligation to ensure that firearms are used safely and responsibly at all times.

Related Posts: